Compact and does not take up space: Perfect for setup in narrow locations. Lightweight so it is easy to carry.
The inner tub has a special surface treatment so bacteria will not adhere to surfaces.
Temperature adjustments are easy; you can tell if the heater is on or off
using the pilot lamp.
Has a cable hole so you can record the change over time of the temperature
sensor.Overheat prevention mechanism which uses a manually recovered thermostat
prevents excessive temperature from rising.
For maintaining samples handled on the clean bench until placed in a large incubator. For chair-side anaerobic incubation for dentists and detecting the campylobacter or helicobacter in food hygiene inspections using an anaero pack.
Note:When running for extended periods continuously, the ambient temperature should be as stable as is possible.
| Code | Model | Specifications | drawing |
| 0156 | Main unit vertical setup | One shelf for vertical setup | (PDF) |
| 0157 | Main unit horizontal setup | One shelf for horizontal setup | (PDF) |
| 0158 | Shelves for vertical setup | 1 shelf | (PDF) |
| 0159 | Shelves for horizontal setup | 1 shelf | (PDF) |
| Type | Vertical setup type | Horizontal setup type |
| Type | Air jacket | |
| Temperature adjustment range | Ambient temperature + 5 to 55 degree C | |
| Tub inside dimensions | 220W x 300D x 270H mm | 310W x 300D x 185H mm |
| Inside volume | Approx. 18L(including door) | Approx. 17.5L (including door) |
| ** Effective inside volume | 220W x 300D x 235H mm | 310W x 300D x 148H mm |
| Outside dimensions (including projecting portions) |
309W x 362.5D x 458.5H mm | 455.5W x 362.5D x 312H mm |
| Total weight | Approx. 5.5 kg | Approx. 4.8 kg |
| Tub material | Cold-rolled stainless steel (SUS304) | |
| Outer packaging material | ABS/AS | |
| Heater | Mica heater 100V 130W | Silicon rubber heater 100V 130W |
| Temperature sensor | Liquid expansion type thermo-detector contact point thermostat | |
| Overheating prevention device | Thermostat āEmanual recovery type | |
| Power | AC100V 50/60 Hz | |
| Maximum power consumption |
130W | |
| Accessories | Shelves (stainless steel), Stem thermometer | |
* Performance outlined in the specifications applies to an ambient temperature of 23degrees C (when there is no load).
** Effective Inner Volume: Inner volume when setup shelf is always on the bottom level.
![]() |